FLOMID-MX Control unit for electromagnetic flowmeters INSTRUCTIONS MANUAL R-MI-Flomid-MX Rev.:2 English version in
10 Once the minimum flow has been configured the set-up returns to the main menu showing flow rate set-up. Pressing the push button the next ite
11 P u l s e w i d t h 6 5ms After the option is chosen, the set-up returns to the main menu. Pressing the push button the ne
124.4.1 Output 1 mode In this screen we select output No 1 to act as an alarm, as an indication of pipe empty or as a batching control output.
13If the alarm option has been selected then the screens for selecting the switching points will appear. O u t p u t 2 O N a t > 0 0
144.6 Preferences P r ef er enc es In this submenu we can configure other parameters, such as the default working screen an
15N o r m a l f l o w +I n v e r t e d f l o w 0 N o r m a l f l o w 0I n v e r t e d f l o w + The sign “+” means that the c
16 To program the languages the use of the push buttons is slightly different from the normal use. 1. Push button - To move to the next cha
17 By pressing the key , the state of the digital outputs will change. By pressing the key , the state of the frequency output will change. By pres
187 STATUS INDICATION During the normal working mode, some symbols can be displayed on the screen which indicate the status of the instrument. I
199 TECHNICAL CHARACTERISTICS 9.1 Power supply Supply voltage: Standard : 220 VAC 50/60Hz, 24 VDC On order : 240 VAC, 110 VAC, 24 V
TABLE OF CONTENTS 1 INTRODUCTION ...
20WARRANTY Tecfluid S.A. GUARANTEES ALL ITS PRODUCTS FOR A PERIOD OF 24 MONTHS, after consignment, against all defects in materials and workmanship.
31 INTRODUCTION The Flomid-MX electronic control unit adapts to the different Flomid and Flomat series electromagnetic flow sensors. The microp
4 - A mains switch must be provided to disconnect the equipment. This switch must be marked as the disconnecting device for the equipment and be w
52.4 Remote partial reset connection Terminal 11 Anode. 12 Cathode. This input is for connecting a remote push button to reset the par
6 2.6 Sensor connection When the sensor is separate from the electronics the sensor cable is connected at the rear of the instrument. The connectio
73. Push button - To change the display between flow rate, total volume or partial volume. - Together with to enter in the set-up mode
84 SET-UP Set-up mode can be accessed by pressing the and push buttons at the same time, to avoid unwanted changes due to accidental access.
94.1.3 Measuring units In this screen the measuring units should be introduced as follows: M e a s ur i ng uni t s l / h The cur