Electronic
converter for level
transmitters
MT03L
Instructions manual
R-MI-MT03L Rev.: 0 English version
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Instructions manual

Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 0 English version

Seite 2

10 In the case of having inductive loads, and to extend the working life of the relay contacts, it is recommended to use overvoltage protection (VDR f

Seite 3

11 (Down / Left) To change to the digit on the left. Into the menu, to scroll down. (Up) To increase the digit. To change the decimal point. Into th

Seite 4

12 To change the access password of the programming menu, select "Programming" in the main menu and then "Password". 5 MAIN MENU T

Seite 5 - 3 INSTALLATION

13 When the "Password" option is selected, a screen that indicates the password status for this menu appears. Selecting “Activate”, the scr

Seite 6

14 Once in the installation menu, the first screen allows to choose between the different options. 6 INSTALLATION PARAMETERS Power on the electronic c

Seite 7

15 6.2 Input In this screen the type of signal from the sensor connected to the MT03L can be chosen. Resistance input is compatible with level transmi

Seite 8

16 Selecting Yes, the device reads the input signal and sets the lower limit level. The same procedure can be done with the capture of top level, plac

Seite 9 - Passive output

17 Finally, in the last row, the selected input type and a number that is related to the value of that input is shown. If when the level changes this

Seite 10

18 7.2 Units In this screen the units for the level indication can be chosen. To select the number of decimals it must be taken into account that the

Seite 11 - 4 OPERATION

19 7.5.1 Relay 1 and relay 2 By selecting one of the two relay outputs, next screen appears with the options which allow to assign the relay to a fun

Seite 12 - 5 MAIN MENU

2 Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction manual allows the installation, configuration and pro

Seite 13

20 Example 1 If the activation point is programmed to 100 cm and the deactivation point is programmed to 90 cm, when the level is zero the output will

Seite 14 - 6 INSTALLATION PARAMETERS

21 Before making a current calibration, be sure that the ammeter used for that is showing a correct value. 8 SERIAL NUMBER 7.5.2.1 Programming of the

Seite 15

22 13 WORKING SCREEN When exiting the menu, the display shows the working screen, indicating the level value in the previously selected units. This sc

Seite 16

23 The USB connector is located at the rear side of the converter. Connect the USB cable at one end to the converter and at the other to the computer

Seite 17 - 7 PROGRAMMING PARAMETERS

24 13.3 Access to installation and programming In order to change the data contained in the "Install" tab, you must enter a password. The d

Seite 18

25 Once the password is written, press “Enter” or "Open", and the installation or programming tab will open. At the bottom of each section t

Seite 19

26 Changing the parameters of this screen you can program the different functions of the equipment. As in the previous paragraph, to program this data

Seite 20

27 13.5 Firmware updates New firmware updates can be published in the website. These updates contain improvements or bug fixes that make the equipment

Seite 21 - 9 SOFTWARE VERSION

28 Once the file is selected, press the “Program” button. A message “Programming device” will appear. The process takes about 90 seconds, after which

Seite 22 - 14 MAINTENANCE

29 14 TECHNICAL CHARACTERISTICS Power supply 90 ... 265 VAC 50, 60 Hz 18 ... 36 VDC Power consumption:  5 VA Resistance input Range: 0 …

Seite 23

3 TABLE OF CONTENTS 1 INTRODUCTION ... 5 2 RECEPTION ...

Seite 24

30 15 DIMENSIONS Panel hole

Seite 25

31 16 TROUBLESHOOTING Problem Probable cause Solution The displayed level is 0 Incorrect input Check that the input type programmed in the menu mat

Seite 26

32 WARRANTY Tecfluid S.A. guarantees all the products for a period of 24 months from their sale, against all faulty materials, manufacturing or perfor

Seite 27

4 8 SERIAL NUMBER ... 21 9 SOFTWARE VERSION ...

Seite 28

5 1 INTRODUCTION MT03L converters are indicators for level measurement applications. The electronic circuit is based on the most advanced technology i

Seite 29

6 3.2 Electrical connection The connection of the equipment is via plug-in connectors, polarized to avoid mistakes when plugged in. The connectors hav

Seite 30 - Panel hole

7 Before starting the wiring of the instrument, check that the supply voltage available is the same as marked on the label of the converter. Termina

Seite 31 - 16 TROUBLESHOOTING

8 Terminal 8 mA (positive, active output) 9 mA 10 mA (negative, passive output) The analog output is galvanically isolated. It can be either

Seite 32

9 Terminal Description Relay 13 Normally open Relay 1 14 Normally closed Relay 1 15 Common Relay 1 16 Normally open Relay 2 17